Maintaining your portable particle analyzer through consistent cleaning and servicing ensures precision, durability, and conformity to sector-specific norms
These devices are sensitive to contamination, environmental factors, and mechanical wear, so a consistent and thoughtful care routine must be followed
Begin each use by inspecting the exterior surfaces for visible dust or debris
Gently clean the exterior with a microfiber cloth moistened in distilled water or an approved non-scratch cleaning solution
Avoid solvents or alcohol-based cleaners unless explicitly approved, as they can degrade plastic components or optical coatings
Pay special focus to the sampling entrance and exhaust vents—they are prime sites for particulate accumulation
Accumulated debris in these zones may obstruct gas flow and compromise measurement accuracy
Use a gentle brush designed for electronics or compressed air at low pressure to remove loose particles
Do not probe the ports with any rigid instrument—this risks irreversible harm to embedded detection elements
Following each session in dusty conditions, activate the purge function with filtered air or nitrogen if available
This helps clear residual particles from the internal chamber and reduces the risk of cross-contamination between samples
The optical pathway—including lenses, mirrors, and emitters—is easily compromised by fingerprints, oil residues, or dust films
Optical cleaning must be performed exclusively by certified technicians with approved equipment and fluids
Use high-purity alcohol-soaked swabs in gentle, spiral motions, beginning at the core and moving radially outward
Wait until no moisture remains—no matter how slight—to avoid electrical shorts or lens fogging
Calibration is not merely a periodic task—it is a core component of maintenance
Follow the manufacturer’s recommended schedule, which may vary depending on usage frequency and environmental conditions
Validate performance using accredited particle standards and maintain a permanent log of all calibration events
When readings become erratic, show systematic drift, or trigger alarms, halt operations and conduct a comprehensive diagnostic along with recalibration
Keep a maintenance log that includes dates of cleaning, calibration, part replacements, and any observed anomalies
The power source requires ongoing evaluation
Never allow complete depletion; recharge when the battery drops below 20%, and store it at 40–60% charge during long dormancy
Exposure to extreme temperatures, both hot and cold, can reduce battery efficiency and damage internal electronics
Never leave the device exposed—always return it to its designated case in a controlled, debris-free space
Maintain humidity below 60% to prevent moisture-induced short circuits and long-term oxidation
Replace consumable parts such as filters, tubing, and seals according to the manufacturer’s guidelines
Visual inspection alone is insufficient—material fatigue and chemical breakdown occur invisibly
Keep spare parts on hand to minimize downtime
Use foam inserts or cushioned cases during transit and never stack items above the analyzer
Training is non-negotiable—every user must be certified in correct operational and maintenance practices
Clear, documented workflows minimize mistakes and 動的画像解析 align team performance with manufacturer expectations
Manufacturers frequently release enhancements—review updates monthly to adopt the latest guidance
By investing time and care into routine cleaning and maintenance, users can rely on their portable particle analyzers for consistent, high-quality data over many years of service